Uni-Solar US-64 [ 1997]

Module efficiency vs. irradiance and cell temperature.

Sandia Array Performance Model Parameters

id1549
created_onFeb. 12, 2019
modified_onFeb. 12, 2019
created_bymikofski
modified_bymikofski
NameUni-Solar US-64 [ 1997]
VintageJan. 1, 1997
Area1.012
Material2
Cells_in_Series11
Parallel_Strings2
Isco5.066
Voco21.71
Impo4.144
Vmpo15.49
Aisc0.00085
Aimp0.00116
C01.121
C1-0.121
Bvoco-0.097
Mbvoc0.0
Bvmpo-0.051
Mbvmp0.0
N3.51
C2-1.24058
C3-3.91126
A01.047
A10.00082115
A2-0.0259
A30.0031736
A4-0.00011026
B01.0
B1-0.00502
B20.0005842
B3-2.3e-05
B43.83e-07
B5-2.31e-09
DTC3.0
FD1.0
A-3.581
B-0.113
C41.059
C5-0.059
IXO4.71
IXXO2.96
C61.188
C7-0.188
NotesSource: Sandia National Laboratories Updated 9/25/2012 Module Database
is_vintage_estimatedFalse
Cell Type3-a-Si