SunPower SPR-230-WHT [2007 (E)]

Module efficiency vs. irradiance and cell temperature.

Sandia Array Performance Model Parameters

id1513
created_onFeb. 12, 2019
modified_onFeb. 12, 2019
created_bymikofski
modified_bymikofski
NameSunPower SPR-230-WHT [2007 (E)]
VintageJan. 1, 2007
Area1.244
Material10
Cells_in_Series72
Parallel_Strings1
Isco5.99
Voco48.7
Impo5.61
Vmpo41.0
Aisc0.00058
Aimp-0.00038
C01.0072
C1-0.0072
Bvoco-0.133
Mbvoc0.0
Bvmpo-0.14
Mbvmp0.0
N1.241
C20.323035
C3-3.49839
A00.9259
A10.07365
A2-0.01912
A30.002416
A4-0.0001223
B01.0
B1-0.002438
B20.0003103
B3-1.246e-05
B42.11e-07
B5-1.36e-09
DTC3.0
FD1.0
A-3.62
B-0.075
C40.9966
C50.0034
IXO5.92
IXXO4.15
C61.0827
C7-0.0827
NotesSource: Sandia National Laboratories Updated 9/25/2012 Module Database
is_vintage_estimatedTrue
Cell Typec-Si