SunPower SPR-225-WHT [2007 (E)]

Module efficiency vs. irradiance and cell temperature.

Sandia Array Performance Model Parameters

id1512
created_onFeb. 12, 2019
modified_onFeb. 12, 2019
created_bymikofski
modified_bymikofski
NameSunPower SPR-225-WHT [2007 (E)]
VintageJan. 1, 2007
Area1.244
Material10
Cells_in_Series72
Parallel_Strings1
Isco5.87
Voco48.5
Impo5.49
Vmpo41.0
Aisc0.0006
Aimp-0.00038
C01.004
C1-0.004
Bvoco-0.132
Mbvoc0.0
Bvmpo-0.139
Mbvmp0.0
N1.221
C20.2911
C3-4.7355
A00.9405
A10.05264
A2-0.00939
A30.00073
A4-1.99e-05
B01.0
B1-0.002438
B20.00031
B3-1.246e-05
B42.11e-07
B5-1.36e-09
DTC3.0
FD1.0
A-3.62
B-0.075
C40.994
C50.006
IXO5.77
IXXO4.05
C61.072
C7-0.072
NotesSource: Sandia National Laboratories Updated 9/25/2012 Module Database
is_vintage_estimatedTrue
Cell Typec-Si