SunPower SPR-210-WHT [2007 (E)]

Module efficiency vs. irradiance and cell temperature.

Sandia Array Performance Model Parameters

id1503
created_onFeb. 12, 2019
modified_onFeb. 12, 2019
created_bymikofski
modified_bymikofski
NameSunPower SPR-210-WHT [2007 (E)]
VintageJan. 1, 2007
Area1.244
Material10
Cells_in_Series72
Parallel_Strings1
Isco5.75
Voco47.7
Impo5.25
Vmpo40.0
Aisc0.00061
Aimp-0.00038
C01.0039
C1-0.0039
Bvoco-0.133
Mbvoc0.0
Bvmpo-0.136
Mbvmp0.0
N1.221
C20.291066
C3-4.73546
A00.94045
A10.052641
A2-0.0093897
A30.00072623
A4-1.9938e-05
B01.0
B1-0.002438
B20.0003103
B3-1.246e-05
B42.11e-07
B5-1.36e-09
DTC3.0
FD1.0
A-3.62
B-0.075
C40.9942
C50.0058
IXO5.65
IXXO3.87
C61.0723
C7-0.0723
NotesSource: Sandia National Laboratories Updated 9/25/2012 Module Database
is_vintage_estimatedTrue
Cell Typec-Si