Solarex MSX-77 [1999 (E)]

Module efficiency vs. irradiance and cell temperature.

Sandia Array Performance Model Parameters

id1484
created_onFeb. 12, 2019
modified_onFeb. 12, 2019
created_bymikofski
modified_bymikofski
NameSolarex MSX-77 [1999 (E)]
VintageJan. 1, 1999
Area0.732
Material11
Cells_in_Series36
Parallel_Strings1
Isco5.0
Voco21.0
Impo4.56
Vmpo16.9
Aisc0.000512
Aimp-0.000148
C00.991
C10.009
Bvoco-0.0808
Mbvoc0.0
Bvmpo-0.0822
Mbvmp0.0
N1.34
C20.12239
C3-7.07424
A00.913
A10.079168
A2-0.015975
A30.0013057
A4-3.7247e-05
B01.0
B1-0.002438
B20.0003103
B3-1.246e-05
B42.11e-07
B5-1.36e-09
DTC3.0
FD1.0
A-3.56
B-0.075
C40.9856
C50.0144
IXO4.88
IXXO3.29
C61.116
C7-0.116
NotesSource: Sandia National Laboratories Updated 9/25/2012 Module Database
is_vintage_estimatedTrue
Cell Typemc-Si