Photowatt PWX100 [2000 (E)]

Module efficiency vs. irradiance and cell temperature.

Sandia Array Performance Model Parameters

id1263
created_onFeb. 12, 2019
modified_onFeb. 12, 2019
created_bymikofski
modified_bymikofski
NamePhotowatt PWX100 [2000 (E)]
VintageJan. 1, 2000
Area0.152
Material11
Cells_in_Series36
Parallel_Strings1
Isco0.71
Voco21.6
Impo0.65
Vmpo17.0
Aisc0.00062
Aimp9.7e-05
C00.994
C10.006
Bvoco-0.0785
Mbvoc0.0
Bvmpo-0.0791
Mbvmp0.0
N1.27
C2-0.1593
C3-12.3925
A00.924
A10.06971
A2-0.01455
A30.001221
A4-3.566e-05
B01.0
B1-0.002438
B20.0003103
B3-1.246e-05
B42.11e-07
B5-1.36e-09
DTC3.0
FD1.0
A-3.47
B-0.0594
C40.99
C50.01
IXO0.701
IXXO0.48
C61.133
C7-0.133
NotesSource: Sandia National Laboratories Updated 9/25/2012 Module Database
is_vintage_estimatedTrue
Cell Typemc-Si