NameKyocera Solar PV75 [2003 (E)]
VintageJan. 1, 2003
Area0.631
Material10
Cells_in_Series36
Parallel_Strings1
Isco4.8
Voco21.0
Impo4.4
Vmpo17.0
Aisc0.00055
Aimp-0.00014
C01.006
C1-0.006
Bvoco-0.0792
Mbvoc0.0
Bvmpo-0.0828
Mbvmp0.0
N1.37
C2-0.117
C3-11.082
A00.921941
A10.0708917
A2-0.0142724
A30.0011709
A4-3.3705e-05
B01.0
B1-0.002438
B20.0003103
B3-1.246e-05
B42.11e-07
B5-1.36e-09
DTC3.0
FD1.0
A-3.56
B-0.075
C40.9921
C50.0079
IXO4.73
IXXO3.12
C61.1281
C7-0.1281
NotesSource: Sandia National Laboratories Updated 9/25/2012 Module Database
is_vintage_estimatedTrue
Cell Typec-Si