BP Solar BP340 [2004 (E)]

Module efficiency vs. irradiance and cell temperature.

Sandia Array Performance Model Parameters

id1105
created_onFeb. 12, 2019
modified_onFeb. 12, 2019
created_bymikofski
modified_bymikofski
NameBP Solar BP340 [2004 (E)]
VintageJan. 1, 2004
Area0.352
Material11
Cells_in_Series36
Parallel_Strings2
Isco2.54
Voco21.8
Impo2.31
Vmpo17.3
Aisc0.00065
Aimp-0.0002
C00.991
C10.009
Bvoco-0.08
Mbvoc0.0
Bvmpo-0.082
Mbvmp0.0
N1.32
C20.12669
C3-6.05171
A00.9415
A10.052728
A2-0.0095876
A30.00067629
A4-1.8111e-05
B01.0
B1-0.002438
B20.0003103
B3-1.246e-05
B42.11e-07
B5-1.36e-09
DTC3.0
FD1.0
A-3.537
B-0.0721
C40.9866
C50.0134
IXO2.51
IXXO1.6
C61.1183
C7-0.1183
NotesSource: Sandia National Laboratories Updated 9/25/2012 Module Database
is_vintage_estimatedTrue
Cell Typemc-Si