AstroPower AP-130 [ 2001]

Module efficiency vs. irradiance and cell temperature.

Sandia Array Performance Model Parameters

id1064
created_onFeb. 12, 2019
modified_onFeb. 12, 2019
created_bymikofski
modified_bymikofski
NameAstroPower AP-130 [ 2001]
VintageJan. 1, 2001
Area1.12
Material10
Cells_in_Series42
Parallel_Strings1
Isco7.35
Voco25.07
Impo6.57
Vmpo19.46
Aisc0.000201
Aimp-0.000423
C00.995
C10.005
Bvoco-0.0954
Mbvoc0.0
Bvmpo-0.0984
Mbvmp0.0
N1.549
C2-0.0665
C3-11.4245
A00.918
A10.068713
A2-0.010438
A30.00072504
A4-2.0182e-05
B01.0
B1-0.002438
B20.0003103
B3-1.246e-05
B42.11e-07
B5-1.36e-09
DTC3.0
FD1.0
A-3.56
B-0.075
C40.989
C50.011
IXO7.26
IXXO4.59
C61.118
C7-0.118
NotesSource: Sandia National Laboratories Updated 9/25/2012 Module Database
is_vintage_estimatedFalse
Cell Typec-Si